Campus solutions

Electricity and Water Monitoring

Read electricity meters and tank levels, review alerts and check local pump protection.

Workflow overview
  1. Measure the campus

    Meter readings, demand and tank levels.

  2. Review alerts

    Unusual load, low levels and flow changes.

  3. Protect locally

    Commissioned pump protection on campus.

What it does

Collect electricity and water readings so estate staff can see usage, investigate unusual patterns and plan follow-up. Start with the main electrical loads and tanks identified in the site survey.

Electricity

Meter readings
Collect readings automatically from the selected circuits and large loads.
Demand alerts
Warn as recorded demand approaches the college’s contracted limit.
After-hours load
Flag load running outside the expected campus schedule for staff review.
Area consumption
Compare monitored blocks, floors or departments in the estate view.

A starting scope of around 10 to 15 meters can focus on the main loads. The survey determines the actual number and installation points; every circuit does not need a meter by default.

Water and pumps

Tank levels
Monitor selected rooftop and ground tanks, with low-level warnings.
Pump protection
Use commissioned local protection to stop a pump in the conditions it is designed to detect, including dry running.
Usage and alerts
Review daily and monthly consumption and investigate unusual night-time flow.

How it helps

Estate staff have readings and history to consult before inspecting a suspected problem. Alerts point to a condition to check; a flow advisory alone does not prove there is a leak.

Management can relate bills to measured activity and discuss changes using the campus’s own baseline. Meter coverage determines how detailed those comparisons can be.

Installation needs a site survey, a qualified electrician and a planned power shutdown. Commissioning checks meter readings, sensor behaviour and pump protection with qualified staff. Agree who receives alerts and how they respond before the system is handed over.

The work, step by step

How the work gets done

Start with measured readings and clear staff responsibilities. Review electrical demand, tank levels and pump condition before deciding what needs attention.

  1. Survey the areas to measure

    Identify buildings, major electrical loads, tanks and pumps. Confirm safe access, existing equipment, the installation window and the staff responsible for maintenance. The survey determines equipment quantities and physical work.

  2. Commission and verify readings

    Qualified staff install the agreed equipment and compare readings with suitable checks. They label circuits and tanks clearly. Pump protection is tested safely as part of commissioning and remains independent of internet access.

  3. Review readings and advisories

    Facilities staff see the reading, unit and last update time. Unusual demand, after-hours use, low tank levels or operating exceptions prompt investigation. A missing or implausible reading must not be treated as a healthy live measurement.

  4. Measure the effect of changes

    Collect 60 to 90 days of baseline readings before claiming savings. Account for occupancy, timetable and seasonal changes. Authorised staff review proposed operating changes and check the resulting records. Energy-saving automation stays off while the baseline is established.

What your team can review

Records and follow-up

Consumption and demand history
Dated readings for the monitored areas support comparisons and follow-up. The report covers installed measurement points, not every unmonitored part of the campus.
Tank and pump condition
Level readings, pump status and protective-trip records help the maintenance team investigate. Tank level needs suitable calibration before it can be treated as a volume.
Advisory and action history
Staff review what prompted an advisory and the recorded outcome of an authorised action. A request being accepted is different from a confirmed equipment action.
Details that help you decide

Common questions

Must we select both electricity and water monitoring?

No. Choose Energy, Water or both for the required monitoring scope. Each needs compatible commissioned equipment and qualified physical work.

Can monitoring guarantee a lower utility bill?

No. Savings depend on measured conditions and the changes the college actually makes. Reports need an agreed baseline and comparable operating conditions.

What happens when the internet or software is unavailable?

Independent local pump protection must remain effective while its own equipment and power are healthy. Remote messages need connectivity. Staff follow the commissioned maintenance and reset procedure after a protective trip.

Before you decide

Measure first. Estimate savings from your campus.

We will not quote a savings percentage before 60 to 90 days of readings from your campus. Energy-saving automation stays off while the baseline is established; protective pump functions are commissioned separately.

Local pump protection can operate during an internet outage while its equipment and power remain healthy. Remote messages wait for connectivity. Authorised local controls remain subject to the equipment’s safety limits; monitoring does not replace qualified maintenance.

Help when you need it

Plan the next step with your team.

Compare the requirements and prices with your team. We also provide consultancy, demonstrations and help with planning. Your proposal records the selected scope, responsibilities and acceptance checks.